Application: |
Wide variety of electronic equipment |
| Product Features: |
Low hold current, Solid state
Radial-leaded product ideal for up to 120VDC/ 120VAC |
| Operation Current: |
100mA~3.75A |
| Maximum Voltage: |
120VDC/120VAC |
| Temperature Range: |
-40ˇăC to 85ˇăC |
| Agency Recognition: |
UL, C-UL & TÜV pending |
|
| |
|
ˇˇ
|
| |
Part
Number |
Hold
Current |
Trip
Current |
Max.Time
to Trip
ˇˇ |
Maximum
Current
ˇˇ |
Rated
Voltage
ˇˇ |
Typical
Power
ˇˇ |
Resistance Tolerance |
|
RMIN |
R1MAX |
| IH,
A |
IT,
A |
at
5xIH |
IMAX,
A |
VMAX,Vdc |
Pd, W |
ohms |
ohms |
| FRA010-120 |
0.10 |
0.20 |
4.0 |
2.0 |
120 |
0.57 |
2.50 |
7.50 |
| FRA017-120 |
0.17 |
0.34 |
3.0 |
2.0 |
120 |
0.59 |
2.00 |
7.00 |
| FRA020-120 |
0.20 |
0.40 |
2.2 |
2.0 |
120 |
0.62 |
1.83 |
4.40 |
| FRA025-120 |
0.25 |
0.50 |
2.5 |
3.0 |
120 |
0.68 |
1.25 |
3.00 |
| FRA030-120 |
0.30 |
0.60 |
3.0 |
3.0 |
120 |
0.74 |
0.88 |
2.10 |
| FRA040-120 |
0.40 |
0.80 |
3.8 |
3.0 |
120 |
0.84 |
0.55 |
1.29 |
| FRA050-120 |
0.50 |
1.00 |
4.0 |
3.0 |
120 |
1.16 |
0.50 |
1.17 |
| FRA065-120 |
0.65 |
1.30 |
5.3 |
3.0 |
120 |
1.32 |
0.31 |
0.72 |
| FRA075-120 |
0.75 |
1.50 |
6.3 |
5.0 |
120 |
1.38 |
0.25 |
0.60 |
| FRA090-120 |
0.90 |
1.80 |
7.2 |
5.0 |
120 |
1.49 |
0.20 |
0.47 |
| FRA110-120 |
1.10 |
2.20 |
8.2 |
5.0 |
120 |
2.25 |
0.15 |
0.38 |
| FRA135-120 |
1.35 |
2.70 |
9.6 |
8.0 |
120 |
2.55 |
0.12 |
0.3 |
| FRA160-120 |
1.60 |
3.20 |
11.4 |
8.0 |
120 |
2.85 |
0.09 |
0.22 |
| FRA185-120 |
1.85 |
3.70 |
12.6 |
8.0 |
120 |
3.15 |
0.08 |
0.19 |
| FRA250-120 |
2.50 |
5.00 |
15.6 |
12.0 |
120 |
3.75 |
0.05 |
0.13 |
| FRA300-120 |
3.00 |
6.00 |
19.8 |
15.0 |
120 |
4.2 |
0.04 |
0.10 |
| FRA375-120 |
3.75 |
7.50 |
24.0 |
15.0 |
120 |
4.8 |
0.03 |
0.08 |
|
| |
IH=Hold
current-maximum current at which the device will not trip at
23ˇăC still air.
IT=Trip current-minimum current at
which the device will always trip at 23ˇăC still air.
V MAX=Maximum voltage device can
withstand without damage at its rated current.
I MAX= Maximum fault current device can
withstand without damage at rated voltage (V
max).
Pd=Typical power dissipated from device when in the tripped
state in 23ˇăC still air environment.
RMIN=Minimum device resistance at 23ˇăC.
R1MAX=Maximum device resistance at
23ˇăC, 1 hour after tripping .
Physical specifications:
Lead material: Tin plated copper, 24 AW
|
| Soldering
characteristics: |
FRA010~FRA090 Tin
plated copper, 22 AWG.
FRA110~FRA375 Tin plated copper, 20 AWG. |
Soldering characteristics:
MIL-STD-202, Method 208E.
Insulating coating:Flame retardant epoxy, meet UL-94V-0
requirement. |
|
| |
 |
 |
 |
FRA 010-120 ~ FRA 090-120
Lead Size: 22AWG,
Ø 0.65 mm Diameter |
FRA 110-120 ~ FRA 375-120
Lead Size: 20AWG,
Ø 0.81 mm Diameter |
|
Part
Number
|
A
|
B
|
C
|
D
|
E
|
F |
|
Maximum
|
Maximum
|
Typical
|
Minimum
|
Maximum
|
Typical |
| FRA010-120 |
7.9 |
12.7 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA017-120 |
7.9 |
12.7 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA020-120 |
7.9 |
12.2 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA025-120 |
7.9 |
12.7 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA030-120 |
7.9 |
13.0 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA040-120 |
8.2 |
14.2 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA050-120 |
9.2 |
14.9 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA065-120 |
9.7 |
14.9 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA075-120 |
10.6 |
15.5 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA090-120 |
11.9 |
15.9 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA110-120 |
13.3 |
18.3 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA135-120 |
15.5 |
20.6 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA160-120 |
17.5 |
22.5 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA185-120 |
19.9 |
24.9 |
5.1 |
7.6 |
5.0 |
3.0 |
| FRA250-120 |
22.5 |
27.5 |
10.2 |
7.6 |
5.0 |
3.0 |
| FRA300-120 |
25.5 |
30.0 |
10.2 |
7.6 |
5.0 |
3.0 |
| FRA375-120 |
29.5 |
34.0 |
10.2 |
7.6 |
5.0 |
3.0 |
|
|
| |
 |
| |
|
| |
 |
| |
A = FRA010-120
B = FRA017-120
C = FRA020-120
D = FRA025-120
E = FRA030-120
F = FRA040-120
G = FRA050-120
H = FRA065-120
I = FRA075-120
J = FRA090-120
K = FRA110-120
L = FRA135-120
M = FRA160-120
N = FRA185-120
O = FRA250-120
P = FRA300-120
Q = FRA375-120
|
|
|
| |


|
| |
 |
| |
|
P/N |
Pcs /Bag
|
Reel/Tape
|
| FRA010-120 |
300
|
1.5K
|
| FRA017-120 |
300
|
1.5K
|
| FRA020-120 |
300
|
1.5K
|
| FRA025-120 |
300
|
1.5K
|
| FRA030-120 |
300 |
1.5K |
| FRA040-120 |
300 |
1.5K |
| FRA050-120 |
300 |
1.5K |
| FRA065-120 |
300 |
1.5K |
| FRA075-120 |
300 |
1.5K |
|
|
|
P/N |
Pcs /Bag
|
Reel/Tape
|
| FRA090-120 |
300
|
1.5K
|
| FRA110-120 |
300
|
600
|
| FRA135-120 |
200
|
600
|
| FRA160-120 |
200 |
----- |
| FRA185-120 |
200 |
----- |
| FRA250-120 |
100 |
----- |
| FRA300-120 |
100 |
----- |
| FRA375-120 |
100 |
----- |
|
ˇˇ
|
| |
| Warning: |
- Operation beyond the specified maximum ratings or
improper use may result in damage and possible electrical
arcing and/or flame.
- PPTC device are intended for occasional overcurrent
protection. Application for repeated overcurrent condition
and/or prolonged trip are not anticipated.
- Avoid contact of PPTC device with chemical solvent.
Prolonged contact will damage the device performance.
|
|
|
All the specifications are subject to
change without previous notice.
|