 |
| |
|
|
Application: |
Wide variety of electronic equipment |
| Product Features: |
Low resistance, High hold current, Solid state,
Radial-leaded product ideal for up to 30V |
| Operation Current: |
900mA~9A |
| Maximum Voltage: |
up to 30V |
| Temperature Range: |
-40<C to 85<C |
| Agency Recognition: |
UL(E211981), C-UL(E211981)
TÜV (R3-50004084) |
|
| |
|
| |
|
|
| |
Part
Number |
Hold
Current |
Trip
Current |
Max.Time
to Trip
|
Maximum
Current
|
Rated
Voltage
|
Typical
Power
|
Resistance Tolerance |
|
RMIN |
R1MAX |
| IH,
A |
IT,
A |
at
5xIH |
IMAX,
A |
VMAX,Vdc |
Pd, W |
ohms |
ohms |
| FRU090-30 |
0.90 |
1.80 |
5.9 |
40 |
30 |
0.6 |
0.070 |
0.22 |
| FRU110-30 |
1.10 |
2.20 |
6.6 |
40 |
30 |
0.7 |
0.050 |
0.17 |
| FRU135-30 |
1.35 |
2.70 |
7.3 |
40 |
30 |
0.8 |
0.040 |
0.13 |
| FRU160-30 |
1.60 |
3.20 |
8.0 |
40 |
30 |
0.9 |
0.030 |
0.11 |
| FRU185-30 |
1.85 |
3.70 |
8.7 |
40 |
30 |
1.0 |
0.030 |
0.09 |
| FRU250-30 |
2.50 |
5.00 |
10.3 |
40 |
30 |
1.2 |
0.020 |
0.07 |
| FRU300-30 |
3.00 |
6.00 |
10.8 |
40 |
30 |
2.0 |
0.020 |
0.08 |
| FRU400-30 |
4.00 |
8.00 |
12.7 |
40 |
30 |
2.5 |
0.010 |
0.05 |
| FRU500-30 |
5.00 |
10.00 |
14.5 |
40 |
30 |
3.0 |
0.010 |
0.05 |
| FRU600-30 |
6.00 |
12.00 |
16.0 |
40 |
30 |
3.5 |
0.005 |
0.04 |
| FRU700-30 |
7.00 |
14.00 |
17.5 |
40 |
30 |
3.8 |
0.005 |
0.03 |
| FRU800-30 |
8.00 |
16.00 |
18.8 |
40 |
30 |
4.0 |
0.005 |
0.02 |
| FRU900-30 |
9.00 |
18.00 |
20.0 |
40 |
30 |
4.2 |
0.005 |
0.02 |
|
| |
IH=Hold
current-maximum current at which the device will not trip at 23<C still
air.
IT=Trip current-minimum current at which the
device will always trip at 23<C still air.
V MAX=Maximum voltage device can withstand
without damage at its rated current.
I MAX= Maximum fault current device can
withstand without damage at rated voltage (V max).
Pd=Typical power dissipated from device when in the tripped state in
23<C still air environment.
RMIN=Minimum device resistance at 23<C.
R1MAX=Maximum device resistance at 23<C, 1 hour
after tripping .
Physical specifications:
Lead material: FRU090~FRU250 Tin plated copper, 24 AWG. FRU300~FRU900
Tin plated copper, 20 AWG.
Soldering characteristics: MIL-STD-202, Method 208E.
Insulating coating:Flame retardant epoxy, meet UL-94V-0 requirement. |
| |
 |
 |
 |
FRU 090-30 ~ FRU 250-30
Lead Size: 24AWG,
Ø 0.51 mm Diameter |
FRU 300-30 ~ FRU 900-30
Lead Size : 20AWG,
Ø 0.81 mm Diameter
|
|
Part
Number
|
A
|
B
|
C
|
D
|
E
|
F
|
|
Maximum
|
Maximum
|
Typical
|
Minimum
|
Maximum
|
Typical
|
| FRU090-30 |
7.4 |
12.2 |
5.1 |
7.6 |
3.0 |
0.9 |
| FRU110-30 |
7.4 |
14.2 |
5.1 |
7.6 |
3.0 |
0.9 |
| FRU135-30 |
8.9 |
13.5 |
5.1 |
7.6 |
3.0 |
0.9 |
| FRU160-30 |
8.9 |
15.2 |
5.1 |
7.6 |
3.0 |
0.9 |
| FRU185-30 |
10.2 |
15.7 |
5.1 |
7.6 |
3.0 |
0.9 |
| FRU250-30 |
11.4 |
18.3 |
5.1 |
7.6 |
3.0 |
0.9 |
| FRU300-30 |
11.4 |
17.3 |
5.1 |
7.6 |
3.0 |
1.2 |
| FRU400-30 |
14.0 |
20.1 |
5.1 |
7.6 |
3.0 |
1.2 |
| FRU500-30 |
14.0 |
24.9 |
10.2 |
7.6 |
3.0 |
1.2 |
| FRU600-30 |
16.5 |
24.9 |
10.2 |
7.6 |
3.0 |
1.2 |
| FRU700-30 |
19.1 |
26.7 |
10.2 |
7.6 |
3.0 |
1.2 |
| FRU800-30 |
21.6 |
29.2 |
10.2 |
7.6 |
3.0 |
1.2 |
| FRU900-30 |
24.1 |
29.7 |
10.2 |
7.6 |
3.0 |
1.2 |
|
|
| |
 |
| |
|
| |
 |
| |
|
 |
| A = FRU090-30 |
B = FRU110-30 |
C = FRU130-30 |
D = FRU160-30 |
| E = FRU185-30 |
F = FRU250-30 |
G = FRU300-30 |
H = FRU400-30 |
| I = FRU500-30 |
J = FRU600-30 |
K= FRU700-30 |
L = FRU800-30 |
| M= FRU900-30 |
|
|
|
|
| |


|
| |
 |
| |
| P/N |
Pcs /Bag
|
Reel/Tape
|
| FRU090-30 |
500
|
3K
|
| FRU110-30 |
500
|
3K
|
| FRU135-30 |
300
|
3K
|
| FRU160-30 |
300
|
3K
|
| FRU185-30 |
300
|
3K
|
| FRU250-30 |
300
|
3K
|
| FRU300-30 |
200
|
1.5K
|
|
|
| P/N |
Pcs /Bag
|
Reel/Tape
|
| FRU400-30 |
200
|
1.5k
|
| FRU500-30 |
200
|
------
|
| FRU600-30 |
100
|
------
|
| FRU700-30 |
100
|
------
|
| FRU800-30 |
100
|
------
|
| FRU900-30 |
100
|
------
|
|
|
| |
| Warning: |
- Operation beyond the specified maximum ratings or
improper use may result in damage and possible electrical
arcing and/or flame.
- PPTC device are intended for occasional overcurrent
protection. Application for repeated overcurrent condition
and/or prolonged trip are not anticipated.
- Avoid contact of PPTC device with chemical solvent.
Prolonged contact will damage the device performance.
|
|
|
All the specifications are subject to
change without previous notice.
|