Application: |
Wide variety of electronic equipment |
| Product Features: |
Low hold current, Solid state, Radial-leaded product ideal
for up to 60V |
| Operation Current: |
50mA ~ 3.75A |
| Maximum Voltage: |
60V |
| Temperature Range: |
-40<C to 85<C |
| Agency Recognition: |
UL(E211981)
C-UL(E211981)
TÜV (R3-50004084) |
|
| |
|
| |
|
|
| |
Part
Number |
Hold
Current |
Trip
Current |
Max.Time
to Trip
|
Maximum
Current
|
Rated
Voltage
|
Typical
Power
|
Resistance Tolerance |
|
RMIN |
R1MAX |
| IH,
A |
IT,
A |
at
5xIH |
IMAX,
A |
VMAX,Vdc |
Pd, W |
ohms |
ohms |
|
FRX005-60
|
0.05
|
0.10
|
5.00
|
40
|
60
|
0.26
|
7.30
|
20.0
|
|
FRX010-60
|
0.10
|
0.20
|
4.00
|
40
|
60
|
0.38
|
2.50
|
7.50
|
|
FRX017-60
|
0.17
|
0.34
|
3.00
|
40
|
60
|
0.48
|
2.00
|
7.00
|
|
FRX020-60
|
0.20
|
0.40
|
2.20
|
40
|
60
|
0.41
|
1.83
|
4.40
|
|
FRX025-60
|
0.25
|
0.50
|
2.50
|
40
|
60
|
0.45
|
1.25
|
3.00
|
|
FRX030-60
|
0.30
|
0.60
|
3.00
|
40
|
60
|
0.49
|
0.88
|
2.10
|
|
FRX040-60
|
0.40
|
0.80
|
3.80
|
40
|
60
|
0.56
|
0.55
|
1.29
|
|
FRX050-60
|
0.50
|
1.00
|
4.00
|
40
|
60
|
0.77
|
0.50
|
1.17
|
|
FRX065-60
|
0.65
|
1.30
|
5.30
|
40
|
60
|
0.88
|
0.31
|
0.72
|
|
FRX075-60
|
0.75
|
1.50
|
6.30
|
40
|
60
|
0.92
|
0.25
|
0.60
|
|
FRX090-60
|
0.90
|
1.80
|
7.20
|
40
|
60
|
0.99
|
0.20
|
0.47
|
|
FRX110-60
|
1.10
|
2.20
|
8.20
|
40
|
60
|
1.50
|
0.15
|
0.38
|
|
FRX135-60
|
1.35
|
2.70
|
9.60
|
40
|
60
|
1.70
|
0.12
|
0.30
|
|
FRX160-60
|
1.60
|
3.20
|
11.4
|
40
|
60
|
1.90
|
0.09
|
0.22
|
|
FRX185-60
|
1.85
|
3.70
|
12.6
|
40
|
60
|
2.10
|
0.08
|
0.19
|
|
FRX250-60
|
2.50
|
5.00
|
15.6
|
40
|
60
|
2.50
|
0.05
|
0.13
|
|
FRX300-60
|
3.00
|
6.00
|
19.8
|
40
|
60
|
2.80
|
0.04
|
0.10
|
|
FRX375-60
|
3.75
|
7.50
|
24.0
|
40
|
60
|
3.20
|
0.03
|
0.08
|
|
| |
IH=Hold
current-maximum current at which the device will not trip at 23<C still
air.
IT=Trip current-minimum current at which the
device will always trip at 23<C still air.
V MAX=Maximum voltage device can withstand
without damage at its rated current.
I MAX= Maximum fault current device can
withstand without damage at rated voltage (V max).
Pd=Typical power dissipated from device when in the tripped state in
23<C still air environment.
RMIN=Minimum device resistance at 23<C.
R1MAX=Maximum device resistance at 23<C, 1 hour
after tripping .
Physical specifications:
Lead material: FRX005~FRX090 Tin plated copper, 24 AWG. FRX110~FRX375
Tin plated copper, 20 AWG.
Soldering characteristics: MIL-STD-202, Method 208E.
Insulating coating:Flame retardant epoxy, meet UL-94V-0 requirement. |
| |
 |
 |
 |
FRX 005-60 ~ FRX 090-60
Lead Size :24AWG,
Ø 0.51 mm Diameter |
FRX FRX 110-60 ~ FRX 375-60
Lead Size : 20AWG,
Ø 0.81 mm Diameter
|
|
Part
Number
|
A
|
B
|
C
|
D
|
E
|
F
|
|
Maximum
|
Maximum
|
Typical
|
Minimum
|
Maximum
|
Typical
|
| FRX005-60 |
7.4
|
12.7
|
5.1
|
7.6
|
3.1
|
1.1
|
| FRX010-60 |
7.4
|
12.7
|
5.1
|
7.6
|
3.1
|
1.1
|
| FRX017-60 |
7.4
|
12.7
|
5.1
|
7.6
|
3.1
|
1.1
|
| FRX020-60 |
7.4
|
12.7
|
5.1
|
7.6
|
3.1
|
1.1
|
| FRX025-60 |
7.4
|
12.7
|
5.1
|
7.6
|
3.1
|
1.1
|
| FRX030-60 |
7.4
|
13.0
|
5.1
|
7.6
|
3.1
|
1.1
|
| FRX040-60 |
7.6
|
13.5
|
5.1
|
7.6
|
3.1
|
1.1
|
| FRX050-60 |
7.9
|
13.7
|
5.1
|
7.6
|
3.1
|
1.1
|
| FRX065-60 |
9.7
|
14.5
|
5.1
|
7.6
|
3.1
|
1.1
|
| FRX075-60 |
10.4
|
15.2
|
5.1
|
7.6
|
3.1
|
1.1
|
| FRX090-60 |
11.7
|
15.8
|
5.1
|
7.6
|
3.1
|
1.1
|
| FRX110-60 |
13.0
|
18.0
|
5.1
|
7.6
|
3.1
|
1.4
|
| FRX135-60 |
14.5
|
19.6
|
5.1
|
7.6
|
3.1
|
1.4
|
| FRX160-60 |
16.3
|
21.3
|
5.1
|
7.6
|
3.1
|
1.4
|
| FRX185-60 |
17.8
|
22.9
|
5.1
|
7.6
|
3.1
|
1.4
|
| FRX250-60 |
21.3
|
26.4
|
10.2
|
7.6
|
3.1
|
1.4
|
| FRX300-60 |
24.9
|
30.0
|
10.2
|
7.6
|
3.1
|
1.4
|
| FRX375-60 |
28.5
|
33.5
|
10.2
|
7.6
|
3.1
|
1.4
|
|
|
| |
 |
| |
|
| |
 |
| |
|
A = FRX005-60
B = FRX010-60
C = FRX017-60
D = FRX020-60
E = FRX025-60
F = FRX030-60
G = FRX040-60
H = FRX050-60
I = FRX065-60
J = FRX075-60
K= FRX090-60
L = FRX110-60
M = FRX135-60
N = FRX160-60
O = FRX185-60
P = FRX250-60
Q = FRX300-60
R = FRX375-60
|
 |
|
| |


|
| |
 |
| |
| P/N |
Pcs /Bag
|
Reel/Tape
|
| FRX005-60 |
500
|
3K
|
| FRX010-60 |
500
|
3K
|
| FRX017-60 |
500
|
3K
|
| FRX020-60 |
500
|
3K
|
| FRX025-60 |
500
|
3K
|
| FRX030-60 |
500
|
3K
|
| FRX040-60 |
500
|
3K
|
| FRX050-60 |
500
|
3K
|
| FRX065-60 |
300
|
3K
|
|
|
| P/N |
Pcs /Bag
|
Reel/Tape
|
| FRX075-60 |
300
|
3K
|
| FRX090-60 |
300
|
3K
|
| FRX110-60 |
300
|
1.5K
|
| FRX135-60 |
200
|
1.5K
|
| FRX160-60 |
200
|
1.5K
|
| FRX185-60 |
200
|
1.5K
|
| FRX250-60 |
100
|
------
|
| FRX300-60 |
100
|
------
|
| FRX375-60 |
100
|
------
|
|
|
| |
| Warning: |
- Operation beyond the specified maximum ratings or
improper use may result in damage and possible electrical
arcing and/or flame.
- PPTC device are intended for occasional overcurrent
protection. Application for repeated overcurrent condition
and/or prolonged trip are not anticipated.
- Avoid contact of PPTC device with chemical solvent.
Prolonged contact will damage the device performance.
|
|
|
All the specifications are subject to